Capacitive Load Unit EM-30-07-03 (300VAR)Description
- Description
Description
This series of capacitive Loads is designed to be used with all AC/DC Generators, Machines and Three Phase Transformer in a training environment. For this purpose the units are enclosed in metal housings and provided with Educational Terminal Boards with 4 mm safety terminals socket and clear synoptic showing the feasible connections. The units are also provided with a reference manual which illustrates their use and typical experiments.
Single & Three phase Capacitive Load 7 steps variable per phase
- Max Power : 3×100 VAR
- Voltage : 240/415 Volt
- Frequency : 50Hz
- Protection : Fuse
MAIN CHARACTERISTICS
- Can be connected in Series, Parallel, Star and Delta configurations.
- Can be connected to AC Single and 3 Phase sources.
- Controlled by 3 x 3 circuit breaker switches for 7 steps selection.
TEST DATA TABLE
At Voltage 240 Volt / Phase, 300 VARs (Max Power 3 x 100 VARs)
No | Positions | Capacitance, XC (Ω) S1 | Capacitance, XC (Ω) S2 | Capacitance, XC (Ω) S3 | Power Absorbed (VARS) | ||
SW1 | SW2 | SW3 | |||||
0 | OFF | OFF | OFF | – | – | – | – |
1 | OFF | OFF | ON | 3183.1 | 3182.3 | 3182.6 | 18.1 |
2 | OFF | ON | OFF | 1591.5 | 1592 | 1591.2 | 36.2 |
3 | OFF | ON | ON | 1061 | 1062 | 1061.3 | 54.3 |
4 | ON | OFF | OFF | 795.8 | 794.5 | 796.8 | 72.4 |
5 | ON | OFF | ON | 636.6 | 636.1 | 635.6 | 90.5 |
6 | ON | ON | OFF | 530.5 | 530.2 | 531.5 | 108.6 |
7 | ON | ON | ON | 457.7 | 456.5 | 458.2 | 126.7 |
No | Positions | Current (A) S1 | Current (A) S2 | Current (A) S3 | Power Absorbed (VARS) | ||
SW1 | SW2 | SW3 | |||||
0 | OFF | OFF | OFF | – | – | – | – |
1 | OFF | OFF | ON | 0.08 | 0.08 | 0.08 | 18.1 |
2 | OFF | ON | OFF | 0.15 | 0.15 | 0.15 | 36.2 |
3 | OFF | ON | ON | 0.23 | 0.23 | 0.23 | 54.3 |
4 | ON | OFF | OFF | 0.32 | 0.31 | 0.32 | 72.4 |
5 | ON | OFF | ON | 0.40 | 0.39 | 0.40 | 90.5 |
6 | ON | ON | OFF | 0.47 | 0.47 | 0.47 | 108.6 |
7 | ON | ON | ON | 0.55 | 0.54 | 0.55 | 126.7 |
EXPERIMENTS COVER
EXPERIMENT 1: BALANCED THREE-PHASE LOADS
Experiment 1.1: Star connection with balance resistive load
Experiment 1.2: Delta connection with balance resistive load
EXPERIMENT 2: UNBALANCED THREE-PHASE LOADS
Experiment 2.1: Star connection with unbalance three-wire resistive load
Experiment 2.2: Star connection with unbalance four-wire resistive load
Experiment 2.3: Delta connection with unbalance resistive load
EXPERIMENT 3: BALANCED THREE-PHASE RL LOADS
Experiment 3.1: Star-Connected with series R-L Load
Experiment 3.2: Delta-Connected with series R-L Load
EXPERIMENT 4: BALANCED THREE-PHASE RC LOADS
Experiment 4.1: Star-Connected with series R-C Load
Experiment 4.2: Delta-Connected with series R-C Load
EXPERIMENT 5: BALANCED THREE-PHASE RLC (SERIES) LOADS
Experiment 5.1: Star-Connected with series R-L-C Load
Experiment 5.2: Delta-Connected with series R-L-C Load
EXPERIMENT 6: BALANCED THREE-PHASE RLC (PARALLEL) LOADS
Experiment 6.1: Star-Connected with parallel R-L-C Load
Experiment 6.2: Delta-Connected with parallel R-L-C Load
Note: Specification May Change Without Prior Notice For Products Continuous Development Process.