Electrical Wiring Installation Trainer EM-58503Description
The system deals with standard installation circuits for all general service lamps and fluorescent lamps in conjunction with our training panel system. This requires no tools so the trainee can concentrate entirely on putting his accrued knowledge into practice. Particular emphasis is placed on adherence to the applicable regulations governing electrical installations.
Safety sockets and Test Lead Set guarantee optimal low-voltage range protection against personal injury during the experiments.
Due to the vertical arrangement of the experimental panels, the experimental set-up can be seen from a far distance and can he adapted step by step to the course of the lessons or lectures.
The experiments permit practice-oriented, hands-on training to be carried out, thus assuring the trainees of the proficiency needed to handle the tasks and the equipment found in this field. The training panels and functional units with block circuit diagrams and signal diagrams permit clear and understandable assembly of the experiment circuits. Beginning with the basic circuits, the student proceeds to tackle more complex circuits in electrical system using a proven step-by-step method designed for didactic results. And of course, the model behind the entire system is the circuitry used in industrial applications.
- Description
Description
Experiments cover the following topics:
- Single phase AC circuits
- Various Lamp And Appliances Circuits
- Standard Installation Circuits
- Switches And Push Buttons Circuit
- Fluorescent Lamps Circuits
- Staircase Lighting circuits and Time-Delay Switching
- Typical electrical signal is observed and measurement
SINGLE PHASE POWER SUPPLY MODULE
EM-10-09-02 |
CURRENT FLOW MODULE
EM-10-04-02 |
· Modular Design · Power Input: 1 Phase 240V, 13A, 50Hz via input 3 pin power cord UK Type. · Protection: Earth leakage circuit breaker and miniature circuit breaker · Complete with START and STOP Push Button · Unit Type : Panel H1 · Terminals: 4mm Safety Sockets (Color Coded) |
Input: 240VAC, 50Hz 1-Phase
|
ON/OFF SWITCH (SINGLE POLE)
EM-10-06-01 |
CHANGE-OVER SWITCH (LEFT)
EM-10-06-02 |
Input: 240VAC, 50Hz 1-Phase Single Pole 1 Gang Switch type: Disconnecting switch |
Input: 240VAC, 50Hz 1-Phase Switch type: Two-way Switch
|
MULTIPLE SWITCH
EM-10-06-03 |
PUSH BUTTON SWITCH
EM-10-06-05 |
Input: 240VAC, 50Hz 1-Phase Switch type: Two-circuit Switch |
Input: 240VAC, 50Hz 1-Phase Switch type: Push button Switch |
CROSS-OVER SWITCH
EM-10-06-06 |
CHANGE-OVER SWITCH (RIGHT)
EM-10-06-07 |
Input: 240VAC, 50Hz 1-Phase Switch type: Intermediate switch |
Input: 240VAC, 50Hz 1-Phase Switch type: Two-way Switch |
SOCKET OUTLET
EM-10-06-09 |
DIMMER
EM-10-05-08 |
Socket Outlet Input: 240VAC, 50Hz 1-Phase Operation: Voltage connector with ground |
Input: 240VAC, 50Hz 1-Phase
|
ANALOG TIMER SWITCH
EM-10-07-04 |
STAIRCASE LIGHTING TIME-DELAY SWITCH
EM-10-07-06 |
Input: 240VAC, 50Hz 1-Phase
|
Input: 240VAC, 50Hz 1-Phase Automatic Staircase Relay 240vac Relay coil: 240VAC |
LOAD BULB MODULE
EM-10-10-02 |
LED DOWNLIGHT
EM-10-10-03 |
Input: 240VAC, 50Hz 1-Phase Load Bulb, AC 240V, 50Hz 1-Phase X 4 Unit |
Input: 240VAC, 50Hz 1-Phase LED Light AC 240V, 50Hz 1-Phase |
HALOGEN DOWNLIGHT
EM-10-10-04 |
INCANDESCENT LAMP
EM-10-10-05 |
Input: 240VAC, 50Hz 1-Phase
|
Input: 240VAC, 50Hz 1-Phase Lamp type: Incandescent |
COMPACT FLUORESCENT LAMP
EM-10-10-06 |
FLUORESCENT LAMP HOLDER (LEFT)
EM-10-10-07 |
Input: 240VAC, 50Hz 1-Phase Lamp type: Compact Florescent With Ballast |
Input: 240VAC, 50Hz 1-Phase
|
FLUORESCENT LAMP STARTER & CAPACITOR
EM-10-10-08 |
MAGNETIC BALLAST
EM-10-10-09 |
Input: 240VAC, 50Hz 1-Phase Nominal Capacitance: 4μF & 2μF |
Input: 240VAC, 50Hz 1-Phase
|
ELECTRONIC BALLAST
EM-10-10-10 |
FLUORESCENT LAMP HOLDER (RIGHT)
EM-10-10-11 |
Input: 240VAC, 50Hz 1-Phase |
Input: 240VAC, 50Hz 1-Phase |
FLUORESCENT LAMP BULB
EM-10-10-12 |
SINGLE PHASE POWER ANALYSIS METER
EM-30-13-14 |
Input: 240VAC, 50Hz 1-Phase
|
Input: 240VAC, 50Hz 1-Phase Display Type: Digital LED Display Measuring Function: Voltage V, Current A, Active Power KWH, Reactive Power VAR, Appearant Power VA, Power Factor PF Measuring Range : Voltage : 0 ~ 250V Current : 0 ~ 5A |
SINGLE PHASE KILOWATT HOUR METER
EM-30-13-18 |
4mm SAFETY STACKABLE TEST LEADS SET & 19MM LINK SET EM-10-10-11 |
Input: 240VAC, 50Hz 1-Phase Type: Moving coil Speed: 1200 Turns/1kw/Hour Voltage coil: 240 VAC Current coil: 5A/15A Accuracy: Class 1.5 |
Leads are capable of 10A current safety plugs. Safety Terminal Socket : 4mm Length: 25cm, 50cm & 100cm Color: Red, Yellow, Blue, Black & Green
|
EXPERIMENTAL TABLE
EM-30-16-01-02 |
EXPERIMENT PANEL FRAME
EM-30-16-02-02 |
5′ Standard Desktop Dimension: Length : 1500mm Width : 800mm Height : 850mm 3 Layer Drawer (Optional)
|
Din Standard A4 With Two Shelves Side Frame: T Shape Dimension: Length : 1450mm Width : 20mm Height : 300mm |
MANUAL
- Manuals written in English that cover introduction to the system, operational procedures and experiments procedures provided.
- Softcopy & hardcopy of Lab sheet for all experiments.
Note: Layout and specification may change without prior notices for products continuous development and improvement process.